KENR8601 91
Troubleshooting Section
Diagnostic Codes
Table 18
Diagnostic Codes
(1)
CID No. / FMI No.
Description
CID 100 - Pressure Sensor (Engin e Oil):
FMI 2 Incorrect signal
FMI 3 Voltag e above n
ormal
FMI 4 Voltag e below normal
CID 110 - Temperature Sensor (Engine Coolant):
FMI 2 Incorrect signal
FMI 3 Voltage above normal
FMI 4 Voltag e below normal
CID 111 - Fluid
Level Sensor (Engine Coolant):
FMI 3 Voltage above normal
CID 168 - Electrical System Voltage:
FMI 3 Voltage above normal
FMI 4 Voltag e below normal
CID 175 - Temperature Sensor (Engine Oil):
FMI 2 Incorrect si
gnal
FMI 3 Voltage above normal
FMI 4 Voltag e below normal
CID 190 - Speed Sensor (Engine):
FMI 2 Incorrect signal
FMI 3 Voltage above normal
CID 248 - CAT D
ata Link:
FMI 9 Abnormal update
CID 268 - EMCP Electronic Control (Generator Set):
FMI 2 Incorrect signal
CID 269 - Sensor Power Supply:
FMI 3 Voltage above normal
FMI 4 Voltage belo
wnormal
CID 333 - Alarm Module Control:
FMI 3 Voltage above normal
FMI 4 Voltag e below normal
CID 3 34 - Spare Output:
FMI 3 Voltage above normal
FMI 4 Voltage bel
ow normal
CID 336 - Switch (Engine Control):
FMI 2
Undefined state
CID 441 - Electronic Governor Relay:
(continued)
(Table 18, contd)
Diagnostic Code
s
(1)
CID No. / FMI No.
Description
FMI 12 Failed component
CID 442 - Generator Fault Relay:
FMI 12 Failed component
CID 443 - Crank Termination Relay:
FMI 12 Failed component
CID 444 - Starting Motor Relay:
FMI 12 Failed compone
nt
CID 445 - Run Relay:
FMI 12 Failed component
CID 446 - Air Shu
toff Relay:
FMI 12 Failed component
CID 4 47 - Fuel Cont rol Relay:
FMI 12 Failed component
CID 448 - Programmable Spare Relay:
FMI 12 Failed component
CID 475 - Relay Driver Module:
FMI 3 Voltage a bove normal
FMI 4 Voltage below normal
CID 500 - EMC P E
lectronic Control (Generator Set):
FMI 12 Failed component
CID 566 - Unexpected Shutdown:
FMI 7 Improper mechanical response
CID 590 - Engine E lectronic Control Modu le:
FMI 9 Abnormal update
CID 770 - Customer C ommunication Module Data
Link:
FMI 9 Abnormal update
CID 858 - Gene
rator Close Breaker:
(2)
FMI 3 Voltage a bove normal
FMI 4 Voltage below normal
CID 859 - Kilowatt Level Output:
FMI 3 Voltage a bove normal
FMI 4 Voltage below normal
CID 1038 - Go v
ernor Adjust Analog Output:
FMI 3 Voltage a bove normal
FMI 4 Voltage below normal
CID 1167 - EPG Circuit Breaker:
FMI 4 Voltage below normal
(continued)