166 KENR8601
Testing and Adjusting Section
g00838765
Illustra
tion 90
Retention of the Connector
(1) Pin Contact
(2) Socket Contact
Note: Thi
s is especially important for intermittent
problems.
a. Use a new p
in contact. Insert the pin contact
into each socket contact o ne at a time in order
to check for a good grip on the pin contact by
the soc k
et contact.
b. Use a new socket contact. Insert the pin
contact
into each socket contact one at a time
in order to check for a good grip on the pin
contact b y the socket contact. The pin contact
are loc
ated on the mating side of the connector.
c. The connector contact should stay connected
when th
e connector is held in the position
shown in Illustration 90. The connector contact
is the pin contact or the socket contact.
Expected Result: The pin contacts and the
socket contacts appear to be OK.
Results:
OK – The pin contacts and the socket contacts
appear to be O K. STOP.
NOT OK – A problem exists with the connector
terminal.
Repair: Replace the connector contact.
STOP.
i02916819
Alarm Module Control - Adjust
SMCS Code: 4490-025
g00482185
Illustration 91
Alarm Module
(1)Plug
For all alarm applications, the low DC volts alarm
setpoint is adjusted by a potentiometer that is located
under access plug (1) on the rear of the module. The
adjustment range is from 8 to 38 volts. The factory
setting of the alarm setpoint is 24 DCV.