100 KENR8601
Troubleshooting Section
Results:
•
OK – The measured resistances match the Table.
Proceed to Test Step 5.
•
NOT OK – The measured resistances match the
Table. The ECS has failed. Proceed to Test Step 7.
Test Step 5. Compare the voltage
between RM-1 and the ECS.
A. Turn the ECS to the S TOP position.
B. Check the voltage between RM- 1 and RM-28.
Take note of the voltage.
C. Check the voltage at contact 10 of the ECS . Take
note of the voltage.
D. Compare the voltage measured between RM-1
and RM-28 with the voltage measured at contact
10.
Expected Result:
The volta ge s are within 2.0 DCV of each other.
Results:
•
OK – The voltages are within 2.0 DCV of each
other. Proceed to Test Step 6.
•
NOT OK – The voltages are not within two volts
of each other.
Repair: The wiring harness is faulty. Repair the
harness or replace the harness.
Proceed to Test Step 7.
Test Step 6. Compare the voltage
between RM-1 and the lower display.
A. Turn the ECS to the S TOP position.
B. Check the voltage between RM- 1 and RM-28.
Take note of the voltage.
C. Check the voltage that is shown on the lower
display. Take note of the voltage.
D. Compare the two voltages.
Expected Result:
The voltage s are within 2.0 V DC of each other.
Results:
•
OK – The voltages are wit hin 2.0 VDC of each
other. The fault is probably an intermittent fault
which is caused by a faulty connector. Inspect the
electrical connectors.
Repair: Refer to Testing and Adjusting, “Electrical
Connector - Inspect”. If the faulty connector can
not be found, repeat this test procedure. If the fault
still remains, replace th e GSC + P.
STOP.
•
NOT O K – The voltages are not within 2 .0 VDC
of each other.
Repair: Replace the GSC+P.
STOP.
Tes t Step 7. Reprogram the GSC+P.
A. Turn the ECS to the STOP position.
B. Program the setpoint P023 to 2 (EUI). Refer
to System Operation, “Engine Generator
Programming OP5-0”.
C. Turn the ECS to the OFF/RESET position. If
applicable, disconnect the jumper wire on the
ECS that is between terminal 6 and terminal 9.
Not all generators will have a jumper wire between
terminal 6 and terminal 9.
D. Verify that the diagnostic code is no long er
present.
E. Replace the OFF R ESET RELAY (ORR). Replace
the jumper wire on the GSC+P relay module
between terminal 1 and 2.
Expected Result:
Setpoint P023 should be programmed to the correct
setting. The diagnostic code should no longer be
present.
Results:
•
OK – Setpoint P023 is programmed to the correct
setting. The diagnostic code is no longer present.
STOP.
•
NOT OK – Setpoint P023 is not programmed to the
correct setting. The diagnostic code is still present.