136 KENR8601
Troubleshooting Section
The GSC+P treats a CID 0566 FMI 07 as a
shutdown fault. Clear the fault from the fault log after
troubleshooting is complete.
Note: This procedure requires many voltage
measurements during simulated engine cranking. F4
is the fuse for starting the e ngine. F4 is located on the
Relay Module (RM). F4 is removed in order to prevent
cranking the engine and starting the engine. Voltage
measurements must be made quickly before the total
cycle crank time (setpoint P017) elapses. The total
cycle crank time is ninety seconds. Refer to Systems
Operation, “Engine/Generator Programming OP5-0”.
If the voltage measurement takes more than ninety
seconds, the GSC+P will generate an overcrank
fault. The overcrank shutdown indicator will FLASH.
In order to continue with a voltage measurement, the
overcrank fault must be reset by turning the Engine
Control Switch (ECS) to OFF/RESET. Then, turn the
ECS to START.
Te st Step 1. PERFORM AN INITIAL
CHECK.
A. Make sure that there are NO OTHER ACTIV E
FAULTS. This means that there are no diagnostic
codes which are showing on the upper display.
This means that no shutdown or alarm indicators
are flashing. Failure to do so may result
in erroneous troubleshooting and needless
replacement of parts. The operator will make
many voltage measurements while the GSC+P
is attempting to crank the engine. If the GSC+P
detects other faults, it will prevent starting by
shutting off the fuel and air to the engine. The
resulting voltage measurements would then be the
exact opposite of the voltage which is expected
in the procedures.
B. Check the fuel level and quality.
C. Check for a plugged fuel filter.
D. Check for a plugged air filter.
E. Refer to the Service Manual for the engine if there
is an obvious fault with the engine or the fuel
system.
F. Check the operation of the air shutoff solenoid (if
present).
Expected Result:
The air shutoff solenoid activates and the air shutoff
solenoid deactivates.
Note: If there is no air shutoff solenoid present,
proceed with the “YES” statement.
Results:
•
YES – The air shutoff solenoid can be activated
and the air shutoff solenoid can be deactivated.
Proceed to Test Step 2.
•
NO – The air shutoff solenoid can NOT be
activated and the air shutoff solenoid can NOT be
deactivated. STOP.
Test Step 2. VERIFY THE DIAGNOSTIC
CODE.
A. Check if the CID 0566 FMI 07 is s howing. This
means t hat t he CID 0566 FMI 07 is active.
Expected Result:
The CID 0566 FMI 07 is showing as an active fault.
Results:
•
OK – Only a CID 0566 FM I 07 is sh owing. STOP.
•
NOT OK – A CID 0566 FMI 07 is NOT showing.
No active CID 0566 FMI 07 exists. STOP.
Test Step 3. CHECK THE SYSTEM
VOLTAGE.
A. With the engine off, measure the system voltage
at the battery. Make a note of this measurement.
This measurement of the system voltage is used
for comparison in future steps of this procedure.
Expected Result:
For a 24 volt system, the system voltage should be
from 24.8 to 29.5 DCV. For a 32 volt system, the
system voltage should be from 33.1 to 39.3 DCV.
Results:
•
OK – The system voltage is correct. STOP.
•
NOT O K – System voltage is NOT correct.
Repair: For troubleshooting, refer to Testing And
Adjusting, “CID 168 Electrical System”.
STOP.