KENR8601 73
Troubleshooting Section
g00614724
Illustrati
on 50
GSC+P Display Area
(1) Dedicated shutdown indicators
(2) Spare fault indicators
(3) Fault shutdown indicator
(4) Fault alarm indicator
(5) Upper display
(6) Lower display
(7) Keypad
(8) DIAG indicator
Faults that a
re detected and diagnosed by the
GSC+P are shown to service personnel in the display
area of the GSC+P. The GSC+P u se s dedicated
shutdown ind
icators (1), fault shutdown indicator
(3), fault alarm indicator (4), “DIAG” indicator (8),
upper display (5) and lower display (6) to tell s ervice
personnel a
bout a fault. Perform the following
procedure in order to identify the fault that is detected
by the GSC+P.
Note: The “DIAG” indicator (8) functions when
diagnostic inform at ion is available from th e G S C+P.
1. Make a note of the indicators that are functioning
ontheleftsideofthe“GSC+P”.
2. View the fault code on the upper display (5). If the
fault alarm indicator (4) is FLASHING and no fault
code is pre
sent on the upper display (5), press the
alarm codes key in order to view the fault code.
3. Makeanote
of whether or not “DIAG” indicator (8)
is FLASH ING ON C ON TINUOUS LY or ABSENT.
4. On the faul
t identification chart, loo k at the
first column. Locate the fault indicator that is
functioning.
5. Go to the s econd column i n t he chart. Find th e
fault code that is presently shown on the upper
display (
5).
6. Go to the third column in the chart which describes
the status of “DIAG” indicator (8).
7. Read the last two columns in order to find the type
of fault and corresponding topic within this module.