KENR8601 101
Troubleshooting Section
Repair: Reprogram the GSC+P. Refer to System
Operation, “Engine Generator Programming
OP5-0”.
STOP.
i02886514
GSC CID 0190 - FMI 02
SMCS Code: 1907-035
Conditions Which Generate This Code:
This diagnostic code is associated with the
engine speed sensor. TheFMI2meansthatthe
Electronic Control M odule (ECM) has determined
that an incorrect signal from the engine speed sensor
has occ urre d.
g00530097
Illustration 61
System Schematic For The Engine Speed Se nsor
The EMCP II+P system monitors the speed of the
engine. The EMCP II+P system uses engine speed
in order to accomplish many tasks. These tasks are
included in the following list.
•
Activating a shutdown for engine overspeed
•
Termin ating e ng ine crank ing
•
Determining the oil step speed
•
Causing the air shutoff solenoid to engage during
some fault shutdowns
The EMCP II+P does not control engine speed. The
engine speed sensor is mounted on the flywheel
housing of the engine.
The sensor creates a sine wave signal. The signal
is created from passing ring gear teeth. The rate of
the signal is one pulse per tooth. The sensor sends
the sine wave signal to the GSC+P. The frequency
of the signal is directly proportional to the speed of
the e ngine.
The GSC+P treats a CID 190 FMI 2 as a shutdown
fault. The engine is not allowed to crank or the
engine is not allowed to run when a CID 190 FMI 2
diagnostic code is active.
Note: The Engine Speed Sensor is commonly
referred to as magnetic pickup.
Note: Engine s that are equipped w ith an electronic
governor have a separate speed sensor. The cable
of the speed sens or that is us ed by the GSC+P is
marked with one of the following numbers: 838-873,
838-973, and 973-938
This troubleshooting procedure is for a C ID 190 FMI
2 that is active or inactive.
The possible causes of a CID 190 FMI 2 are listed
below.
•
The frequ ency of the signal is beyond accepted
limits. There is a short to the battery negative
terminal (“BATT-”).
•
The air gap of the speed sensor is too large.
Clear the diagnostic code from the fault log after
troubleshooting is complete.
Test Step 1. CHECK THE HARNESS AND
THE SPEED SENSOR.
A. Turn the En gine Co nt rol Switch ( ECS) to
OFF/RESET.
B. Disconnect the harness connector from the
GSC+P.
C. At the GSC+P harness connector, measure the
resistance from pin “1” to pin “2”.
Expected Result:
The resistance should be from 100 to 350 ohms.
Results:
•
OK – There is probably an intermittent problem.
Proceed to Test Step 2.
•
NOT OK – The harness wiring or the speed sensor
has failed. Proceed to Test Step 3.
Test Step 2. CHECK FOR AN
INTERMITTENT FAULT.
A. Turn the ECS to OFF/RESET.
B. Turn the ECS to STOP.
C. Check the upper display for a CID 190 FMI 2.