156 KENR8601
Troubleshooting Section
Diagnostic System
Procedures
i02892285
AL Fault Code
SMCS Code: 4490-035
Table 23
AL Fault Code Troubleshooting
AL Fault Code
Description Troubleshoot
ing
AL1 High Water Temp erature Alarm
Coolant temperature increases to within 6°C (11°F)
of setpoint P015.
Refer to the Troubleshooting, “Troubleshooting
Dedicated Shutdown Indicators”.
AL2
Low Engine Coolant Temperature Alarm
Coolant temperature decreases to setpoint P01 6.
Refer to the Troubleshooting, “Troubleshooting
Dedicated Shutdown Indicators”.
AL3
Low Engine Oil Pressure Alarm
Oil pressu re drops to within 34 kPa (5 psi) of the
P013 or P014 setpoin t.
Refer to the Troubleshooting, “Troubleshooting
Dedicated Shutdown Indicators”.
AL4
Fault Detect
ed By Engine ECM
TheengineECMdetectsanalarmfaultora
shutdown fault.
Refer to the a
ppropriate engine troubleshooting
service manua l.
AL5
Low Engine Coolant Level Fault
Coolant level drops belo w the probe of the coolant
loss sensor.
Check level of engine coolant. The level of engine
coolant must be a bove the probe of the sensor.
Check for CID 111 fau lts. Perform the electrical
connector inspection test. Refer to the Testing and
Adjusting, “Electrical Connector - Inspect”.
AL6
High Engine Oil Temp Fault
Oil temperat
ure increases to within 6°C (11°F) of
setpoint P026.
Check level of engine coolant. The level of engine
coolant mus
t be above the probe of sensor. Che ck
fan belt, e tc. Check P026 setpo int.
AL7
Generator Overvoltage Fault
Line to line voltages rises above the P102 or P105
setpoints.
Refer to the service manual for the voltage regulator
that is being used. Check P101 through P106
setpoints.
AL8
Generator Undervoltage Fault
Line to line
voltage drops below the P108 or the
P111 setpoints.
Refer to the service manual for the voltage regulator
that is bein
g use d. Check P107 through P112
setpoints. Refer to the engine service manual for
the cause of low engine spee d. If engine speed is
reduced an
d the engin e control switch (ECS) is
NOTinSTOP,theGSC+Pwillissuethisfault.
AL9
Generator Overfrequency Fault
Frequency rises above the P114 or P117 setpoints.
Refer to the Troubleshooting, “Indicator For Engine
Overspeed”. Check setpoints P113 through P118.
AL10
Generator Underfrequency Fa ult
Frequency drops be low the P120 or P123
setpoints
.
Refer to the engine service manual for a caus e of
low engi ne speed. If engine speed is reduced and
the ECS is N
OT in STOP, t he GSC+P will issue this
fault. Check setpoints P119 through P1 24.
AL11
Generator Reverse Power Fault
Reverse power rises above the P126 setpoint.
Refer to the engine service manual for a caus e of
lost engine power. Check setpoints P1 25 throu gh
P127.
AL12
Generator Phase Overcurrent Fault
Phase cur
rent rises above the P129 or P134
setpoints.
Check for a cause of the overcurrent.
Check set
point P029 and setpoints P128 through
P135.
(continu