Leaks may provide fuel for fires. Consult your Caterpillar dealer for repair or for replacement parts. Use
genuine Caterpillar parts or the equivalent, for capabilities of both the pressure limit and temperature limit.
Ether
Ether (if equipped) is commonly used in cold weather applications. Ether is flammable and poisonous.
Follow the correct cold engine starting procedures. Refer to the section in the Operation and Maintenance
Manual with the label "Engine Starting".
Do not spray ether into an engine if the machine is equipped with a thermal starting aid for cold weather
starting.
Use ether in well ventilated areas. Do not smoke while you are replacing an ether cylinder or while you are
using an ether spray.
Do not store ether cylinders in living areas or in the operator compartment of a machine. Do not store ether
cylinders in direct sunlight or in temperatures above 49° C (120.2° F). Keep ether cylinders away from open
flames or sparks.
Dispose of used ether cylinders properly. Do not puncture an ether cylinder. Keep ether cylinders away from
unauthorized personnel.
Fire Extinguisher
As an additional safety measure, keep a fire extinguisher on the machine.
Be familiar with the operation of the fire extinguisher. Inspect the fire extinguisher and service the fire
extinguisher regularly. Follow the recommendations on the instruction plate.
Consider installation of an aftermarket Fire Suppression System, if the application and working conditions
warrant the installation.