Automatic Level Control (2)
Automatic Level Control - The Automatic
Level Control maintains the selected angle of
the work tool as the loader lift arms are
raised. Press on the bottom of the switch in
order to activate the automatic level control.
Press on the top of the switch in order to
deactivate the automatic level control.
Note: The Automatic Level Control keeps a load at the selected angle when the lift arms are raised. The
Automatic Level Control is not designed to maintain the selected angle of the work tool when the lift arms
are lowered.
Auxiliary Electrical Control (3)
Illustration 2 g01107114
Typical electrical connection on the loading arm
Auxiliary Electrical Control - The
auxiliary electrical control supplies
continuous electrical power to pin (H) that is
located on the loader arm. Press on the
bottom of the switch in order to turn on
electrical power. Press on the top of the
switch in order to turn off electrical power.
Work Tool Coupler Control (4)