RENR5622 99
Troubleshooting Section
g01149844
Illustration 38
Terminal locations for the ether start relay and for the ether hold
relay
g01204310
Illustration 39
P1 E CM connector
(P1-5) Digital return
g01204311
Illustrat
ion 40
P2 ECM connector
(P2-10) Ether hold re lay
(P2-20) Ether request
(P2-31) Ether start relay
Test Step 1
. Inspect Electrical Connectors
and Wiring
A. Turn the keyswitch to the OFF position.
B. Thoroughly inspect the ECM connectors
J1/P1. Inspect all of the other connectors.
Refer to T
roubleshooting, “Inspecting Electrical
Connectors” for details.
C. Perform a
45 N (10 lb) pull test on each of the
wires in the ECM connector that are associated
with the circuit.
D. Check the ECM connector (allen head screw)
for the proper torque. Refer to Troubleshooting,
“Inspec
ting Electrical Connectors” for details.
E. Check the harness and the wiring for abrasion
and for p
inch points.
Expected Result:
All connectors, pins, and sockets are completely
coupled and/or inserted. The harness and wiring are
free of c
orrosion, of abrasion, and of pinch points.