112 RENR5622
Troubleshooting Section
Note: The digital return will no longer be connected to
the other senso
rs and switches. Additional diagnostic
codes will be generated from the ECM. Clear the
codes after you complete this test.
F. Observe the status of the ground level shutdown
switch on Cat ET.
G. Turn the keyswitch to the OFF position.
H. Remove the sho
rt between P1-28 and P1-5.
I. Short the wire jumpers in P1-23 and P1-5.
J. Turn the keyswitch to the ON position.
K. Observe the st
atus of the ground level shutdown
switch on Cat ET.
L. Turn the keysw
itch to the OFF position.
M. Remove the short between P1-23 and P1-5.
Expected Result:
The status re
ads “OFF” when the short is between
P1-28 and P1-5. The status reads “ON” when the
short is between P1-23 and P1-5.
Results:
•
OK – The statu
s reads “OFF” when the short is
between P1-28 and P1-5. The status reads “ON”
when the short is between P1-23 and P1-5. The
status is co
rrect on Cat ET.
Repair: The problem is in the harness between
the ECM conn
ector and the ground level shutdown
switch. Repair the harness or the connector.
STOP.
•
Not OK – The status does not read “OFF” when
the short is
between P1-28 and P1-5. The status
does not read “ON” when the wire short is inserted
between P1-23 and P1-5. The status is incorrect
on Cat ET.
Repair: Replace the ECM. Refer to
Troublesh
ooting, “Replacing the ECM”.
STOP.
i02411251
Injecto r Solenoids
SMCS Code: 1290
-038-JV
System Operation Description:
Use this procedure to troubleshoot the electrical
system if a problem is suspected with the injectors
or if any one of
the diagnostic codes in Table 36 is
active or easily repeated.