RENR5622 65
Troubleshooting Section
Diagnostic Fun
ctional
Tests
i02408931
Analog Sensor (Active)
SMCS Code: 557
4-038
System Operation Description:
Use this procedure to troubleshoot the electrical
system if a problem is suspected with the sensors
or if any one o
f the diagnostic codes in Table 25 is
active or easily repeated.
Table 25
Diagnostic Codes Table
Description
Conditions w
hich Generate this Code
System Respo
nse
MID 0036 - CID 0101 - FMI 03
Crankcase Pressure open/short to +batt
The Electronic Control Module (ECM)
detects signal voltage that is above
normal for one second.
The ECM has been powered for at least
three seconds.
MID 0036 - CID 0101 - FMI 04
Crankcase Pressure short to ground
The ECM detects signal voltage that is
below normal for one second.
The ECM has been powered for at least
three seconds.
The code is logged.
The value of the parameter is set to
zero.
MID0036-CID0110-FMI03Engine
Coolant Temperature open/short to
+batt
The ECM detects signal voltage that is
above normal for one second.
The ECM has been powered for at least
three seconds.
MID 0036 -
CID 0110 - FMI 04 Engine
Coolant Temperature short to ground
The ECM de
tects signal voltage that is
below normal for one second.
The ECM has been powered for three
seconds.
The code is logged.
The value of the parameter is set to
−40 °C (−40
°F).
MID0036-CID0273-FMI03Turbo
Outlet Pressure open/short to +batt
The ECM detects signal voltage that is
above normal for one second.
The ECM has been powered for at least
three seconds.
MID0036-CID0273-FMI04Turbo
Outlet Pressure short to ground
The ECM detects signal voltage that is
below normal for one second.
The ECM has been powered for three
seconds.
The code is logged.
The value of the parameter is set to
zero.
MID 0036 - CID 0274 - FMI 03
Atmospheric Pressure open/short to
+batt
The ECM detects signal voltage that is
above normal for one second.
The ECM has been powered for at least
three seconds.
MID 0036 - CID 0274 - FMI 04
Atmosp
heric Pressure short to ground
The ECM detects signal voltage that is
below n
ormal for one second.
The ECM has been powered for three
seconds.
The code
is logged.
The value of the parameter is set to
45kPa(6.5psi).
(continued)