RENR5622 109
Troubleshooting Section
Repair: Replace the ECM. Refer to
Troubleshooti
ng, “Replacing the ECM”.
Verify that the problem is resolved.
STOP.
i02411006
Ground Level S
hutdown
Switch
SMCS Code: 190
1-038
System Operation Description:
Use this procedure in order to troubleshoot a problem
with the circuit for the ground level shutdown switch
or use this pr
ocedure if the following diagnostic code
is active.
Table 35
Diagnostic Code
Description
Conditions
which Generate this Code
System Resp
onse
MID 0036 - CID 0267 - FMI 02 Incorrect
Engine Shutdown Switch inputs
The two inputs from the ground level
shutdown switch are in the same state.
Thecodeisactiveandthecodeis
logged.
The ground level shutdown switch provides the
ability to shut down the engine. The engine’s
Electronic Control Module (ECM) remains active.
The Caterpillar Electronic Technician (ET) can be
used to communicate with the ECM. The ground
level shutdown switch must be returned to the RUN
position and the keyswitch must be cycled to the OFF
position before the ECM will allow the engine to start.
To shut down the engine, lift the red cover guard
and toggle the ground level shutdown switch to the
SHUTDOWN position. The ECM reads the position
of the ground level shutdown switch. If the engine
is running, the ECM disables the fuel injection. The
ECM will not allow the engine to start if the engine
is not running.
The voltage at the ECM input P1-23 of the ground
levelshutdownswitchshouldbe11.5±0.5VDC
withthegroundlevelshutdownswitchintheRUN
position. The voltage at the ECM input P1-28 of the
ground level shutdown switch should be less than
0.5 VDC with the ground level shutdown switch in the
RUN position.