156 RENR5622
Troubleshooting Section
E. Install the jumper wire(s) into the terminal
location(s) fo
r the wastegate solenoid at the ECM
connector.
F. Connect the EC
M connectors.
G. Check the operation of the ECM by creating
an open at the E
CM:
a. Hold the loose end of the jumper wires away
from any compo
nents in order to create an
open circuit condition.
b. Turn the keys
witch to the ON position.
c. Proceed to the “Diagnostic Overrides” screen
on Cat ET.
d. Select the override for the wastegate solenoid
on Cat ET.
e. Set the override for the wastegate to 100
percent.
f. Monitor the “Active Diagnostic Code” screen
on Cat ET.
Check the wastegate solenoid for an active 05
diagnostic
code.
Note: Wait at least 30 seconds so that any codes
may become a
ctive.
g. Turn the keyswitch to the OFF position.
H. Check the operation of the ECM by creating a
short circuit at the ECM:
a. Short the jumpers for the return wire and the
output wire together.
b. Turn the keyswitch to the ON position.
c. Proceed to t
he “Diagnostic Overrides” screen
on Cat ET.
d. Select the
override for the wastegate solenoid
on Cat ET.
e. Set the ove
rride for the wastegate to 100
percent.
f. Monitor th
e “Active Diagnostic Code” screen
on Cat ET.
Check the w
astegate solenoid for an active 06
diagnostic code.
Note: Wait
at least 30 seconds so that any codes
may become active.
I. Turn the keyswitch to the OFF position. Reconnect
all wires to the
original configuration.
Expected Result:
A 05 diagnostic code is active when the wires
from the wastegate solenoid are open at the ECM
connector. A 0
6 diagnostic code is active if the wires
from the wastegate solenoid are shorted at the ECM
connector.
Results:
•
OK – The ECM is
operating properly. The problem
is in the wiring between the ECM and the connector
for the wastegate solenoid.
Repair: Repair the connectors or wiring and/or
replace the connectors or wiring.
STOP.
•
Not OK – On e of
the following conditions exists:
The05diagnosticcodeisnotactivewhenthewire
for the wastegate solenoid is disconnected. The 06
diagnostic
code is not active when the wire jumper
is installed.
Repair: Rep
lace the ECM. Refer to
Troubleshooting, “Replacing the ECM”.
Verify that the problem is resolved.
STOP.