RENR5622 37
Troubleshooting Section
i02418528
Boost Pressure Abov e Normal
SMCS Code: 1000
-035; 1901-038
Use this procedure in order to troubleshoot a high
boost pressure
or the following event code. Refer to
Troubleshooting, “Event Code List” for information on
specific trip points for the event codes.
Table 16
Event Code
Description
Conditions which Generate this Code System Response
E092 Boost P ressure Above Normal The actual boost pressure is above the
desired boost pressure.
The code is logged and the code is
active.
Probable Causes
•
Le
aking wastegate diaphragm
•
Air supply
•
Wrong Full Load Setting (FLS)
Recommended Actions
Le
aking Wastegate Diaphragm
Verify that the exhaust bypass valve for the wastegate
ca
n open. Use Caterpillar Electronic Technician (ET)
to override the wastegate to 100 percent. Perform a
torque converter stall test. After 30 seconds, a low
b
oost pressure event should result. If a low boost
pressure event occurs, the wastegate is opening
properly.
Air Supply
V
erify that the air supply to the wastegate control
valveisatleast345kPa(50psi).
W
rong FLS
Check that the FLS is correct.
i02418529
Boost Pressure Below Normal
SMCS Code: 1000-035; 1901-038
U
se this procedure in order to troubleshoot a low
boost pressure or the following event code. Refer to
Troubleshooting, “Event Code List” for information on
specific trip points for the event codes.