66 RENR5622
Troubleshooting Section
(Table 25, cont
d)
Diagnostic Codes Table
Description
Conditions which Generate this Code System Response
MID 0036 - CID 0275 - FMI 03 Right
Turbo Inlet Pressure open/short to +batt
The ECM detects signal voltage that is
above normal for one second.
The ECM has been powered for at least
three seconds.
MID 0036 - CID 0275 - FMI 04 Right
Turbo Inlet Pressure short to ground
The ECM detects signal voltage that is
below normal for one second.
The ECM has been powered for three
seconds.
The code is logged.
The value of the parameter is set to
45kPa(6.5psi).
MID 0036 - CID 0276 - FMI 03 Left
Turbo Inlet Pressure open/short to +batt
The ECM detects signal voltage that is
above normal for one second.
The ECM has been powered for at least
three seconds.
MID 0036 - CID 0276 - FMI 04 Left
Turbo Inlet Pressure short to ground
The ECM detects signal voltage that is
below normal for one second.
The ECM has be
en powered for three
seconds.
The code is logged.
The value of t
he parameter is set to
45kPa(6.5psi).
MID 0036 - CID 0279 - FMI 03
Aftercooler Temperature open/short to
+batt
The ECM detects signal voltage that is
above normal for one second.
The ECM has been powered for at least
three seconds.
MID 0036 - CID 0279 - FMI 04
Aftercooler Temperature short to ground
The ECM detects signal voltage that is
below normal for one second.
The ECM has been powered for three
seconds.
The code is logged.
The value of the parameter is set to
−40 °C (−40 °F).
MID 0036 - CID 0542 - FMI 03 Unfiltered
Engine Oil Pressure open/short to +batt
The ECM detects signal voltage that is
above normal for one second.
The ECM has been powered for at least
three seconds.
MID 0036 - C
ID 0542 - FMI 04 Unfiltered
Engine Oil Pressure short to ground
The ECM det
ects signal voltage that is
below normal for one second.
The ECM has been powered for three
seconds.
The code is logged.
The value of the parameter is set to
500 kPa (75
psi).
MID 0036 - CID 0543 - FMI 03 Filtered
Engine Oil Pressure open/short to +batt
The ECM detects signal voltage that is
above normal for one second.
The ECM has been powered for at least
three seconds.
MID 0036 - CID 0543 - FMI 04 Filtered
Engine Oil Pressure short to ground
The ECM detects signal voltage that is
below normal for one second.
The ECM has been powered for three
seconds.
The code is logged.
The value of the parameter is set to
500kPa(75psi).
MID 0036 - CID 0829 - FMI 03 Rear
Aftercool Temperature open/short to
+batt
The ECM detects signal voltage that is
above normal for one second.
The ECM has been powered for at least
three seconds.
MID 0036 - CID 0829 - FMI 04 Rear
Afterc
ool Temperature short to ground
The ECM detects signal voltage that is
below n
ormal for one second.
The ECM has been powered for three
seconds.
The code
is logged.
The value of the parameter is set to
−40 °C (−40 °F).
System Operation
Use this procedure to troubleshoot any suspect
problems with the following sensors:
•
Aftercooler temperature sensor (rear)
•
Aftercooler temperature sensor (front)
•
Atmospheric pressure sensor