98 RENR5622
Troubleshooting Section
The device driver in the second circuit provides a
return path to t
he ECM from the coil of the ether hold
relay. The other side of the coil is connected to the
+Battery. The ECM monitors current flow in the circuit
in order to det
ermine if there is a problem in the
circuit. The ECM monitors current flow on the device
driver from the coil of the ether hold relay. If current
is below a thr
eshold on the device driver, the ECM
will generate a 546-05 diagnostic code. If current
is above a threshold on the device driver, the ECM
will genera
te a 546-06 diagnostic code. If a 546-06
diagnostic code is generated, the ECM will latch the
device driver open for overcurrent protection.
g01204307
Illustration 3 7
Typical schematic