RENR5622 27
Troubleshooting Section
(Table 8, contd
)
Default Conditions and System Response
Event Code Conditions which Generate this Code System Response
E072 Oil Level Low Mark
Theoillevelswitchopens. Thecodeisactiveandthecodeis
logged.
E073 Oil Filter Differential Pressure
High
E074 Oil Filter Differential Pressure
Very High
The oil filter differential pressure is
above the trip point temperature.
The warning for the oil filter differential
pressure is determined by subtracting
the filtered oil pressure from the
unfiltered oil pressure.
Thecodeisactiveandthecodeis
logged.
E092 Boost P ressure Above Normal The actual boost pressure is above the
desired boost pressure by the trip point
pressure.
Engine speed is between 1275 and
1800 rpm.
Thecodeisactiveandthecodeis
logged.
The fuel is derated by 30 percent. The
timing is retarded to four degrees before
top dead center. The code is latched
until power is cycled to the ECM.
E093 Boost Pressure Below Normal The actual boost pressure is below the
desired boost pressure by the trip point
pressure.
Engine speed is between 1275 and
1800 rpm.
Thecodeisactiveandthecodeis
logged.
The fuel is derated by 30 percent. The
timing is retarded to four degrees before
top dead center. The code is latched
until power is cycled to the ECM.
E095 Fuel Filter Restriction Warning
The restriction across the fuel filter i s
greater than the trip point pressure. The
fuel filte
r differential pressure switch
opens.
Thecodeisactiveandthecodeis
logged.
E098 Engine Prelube Override
The engine has started without
completing the engine prelubrication.
Thecodeisactiveandthecodeis
logged.
E100 Low Engine Oil Pressure Warning The engin
e oil pressure is below a map
dependent value. The oil pressure is
below this value for the delay time.
Thecodei
sactiveandthecodeis
logged.
E101 High Crankcase Pressure
Warning
Engine crankcase pressure is above
trip point pressure for the delay time.
Thecodeisactiveandthecodeis
logged.
E190 Engine Overspeed Warning The engine rpm has exceeded the trip
point for engine overspeed for the delay
time.
Thecodeisactiveandthecodeis
logged.
E265 User Defined Shutdown The ECM detects ground on the input
for the
user defined shutdown.
Thecodeisactiveandthecodeis
logged.
E272 Inlet Air Restriction Warning The inlet air restriction is above the trip
point pressure for the delay time.
Thecodeisactiveandthecodeis
logged.
E279 High Aftercooler Te mperature
Warning
The aftercooler temperature is above
the trip point temperature for the delay
time.
Thecodeisactiveandthecodeis
logge
d.