SEBU8088-06 123
Maintenance Section
Water Pump - Inspect
Excessive cool
ant leakage may indicate the need
to replace the water pump seal. For the removal of
water pump and the installation of water pump and/or
seals, refer t
o the Service Manual for the engine or
consult your Caterpillar dealer.
•
Inspect the l
ubrication system for leaks at the front
crankshaft seal, the rear crankshaft seal, the oil
pan, the oil filters and the valve cover.
•
Inspect the Closed Crankcase Ventilation (CCV)
filter, if equipped. If the restriction indicator is
visible, ser
vice the CCV.
•
Inspect the fuel system for leaks. Look for loose
fuel line cla
mps.
•
Inspect the piping for the air inlet system and the
elbows for c
racks and for loose clamps.
•
Inspect the alternator belt and the accessory drive
belts for cr
acks, breaks or other damage.
Belts for multiple groove pulleys must be replaced as
matched set
s. If only one belt is replaced, the belt will
carry more load than the belts that are not replaced.
The older belts are stretched. The additional load on
the new bel
t could cause the belt to break.
•
Drain the water and the sediment from fuel tanks
on a daily b
asis in order to ensure that only clean
fuel enters the fuel system.
•
Inspect th
ewiringandthewiringharnessesfor
loose connections and for worn wires or frayed
wires.
•
Inspect the ground strap for a good connection and
for good condition.
•
Inspect the engine-to-frame ground strap for a
good connection and for good condition.
•
Disconnect any battery chargers that are not
protected against the current drain of the starting
motor. Ch
eck the condition and the electrolyte level
of the batteries, unless the engine is equipped with
a maintenance free battery.
•
Check the condition of the gauges. Replace any
gauges that are cracked. Replace any gauges that
can not b
e calibrated.
Inspect
the Generator
Refer to Safety Section, “Generator Isolating for
Mainten
ance” for information regarding the procedure
to safely isolate the generator.
A visual inspec
tion should be initially directed at
the areas that are most prone to damage and
deterioration. The most prone areas to damage and
deterioratio
narelistedbelow:
Ground insulation – Ground insulation is insulation
that is inten
ded to isolate components that are
carrying current from components that are not
carrying current.
Support insulation – Support insulation is usually
made from one of the following items: a compressed
lamination o
f fibrous materials, polyester, or felt pads
that have been impregnated with various types of
bonding agents.
There are many different types of damage that can
occur in these areas. Several of the different types of
damage are l
isted below:
Thermal aging – Thermal aging can cause the
degradati
on of insulation or the deterioration of
insulation. An examination of the coils may reveal
that the insulation has expanded into the ventilation
ducts. Thi
s is the result of a loss of bond which
will cause the insulation material to separate. The
insulation material could also separate from the
conducto
rs on the windings.
Abrasion – The surfaces of coils and the surfaces
of connec
tors may be damaged by abrasion. These
surfaces may also be damaged by contamination
from other sources. An example of these sources
would be c
hemicals or abrasive substances.
Cracking – Cracking of insulation may result from
mechani
cal stress. The structure that is used to brace
the stator winding will become loose if the problem
is not corrected. Further mechanical damage or
electri
cal damage may also result.
Erosion – Erosion can be caused when foreign
substan
ces rub against the insulation that is on the
surface of the coil .
i01057943
Water Pump - Inspect
SMCS Co
de: 1361-040
A failed water pump might cause severe engine
overhe
ating problems that could result in the following
conditions:
•
Cracks
in the cylinder head
•
Apistonseizure
•
Other potential damage to the engine