70
Operation Section (D6T LGP (OEM)) WEBM1000
Machine Operation
Table 9
WARNING OPERATION
Warning
Category
Stat
us Indicators
(1)
(1) The active status indicators are marked with an X.
“Operator Action Required” “Possible Result ”
(2)
(2) This is the possible result, if the operator takes no action.
“Action Lamp
Flashes”
“Action
Alarm
Sounds ”
Monitoring
System Display
1 X
(3)
(3) Some level I warnings will be logged only.
No immediate action is
required. The system needs
attention soon.
No machine damage
occurs. Minor
reductions in machine
performance may
occur.
2 X
(4)
(4) The front action lamp flashes amber. The rear action lamp flashes red.
X Change machine operation or
perform maintenance to the
system.
Severe damage to
components can occur.
3 X
(5)
(5) Both action lamps flash red.
X
(6)
(6) The action alarm sounds.
X Immediately perform a safe
engine shutdown.
(7)
(7) Engine overspeed does not require engine shutdown. Engine overspeed requires applying the travel control pedal in order to reduce the track speed
immediately. This action reduces the engine speed immediately.
Injury to the operator or
severe damage to
components can occur.
If a fault indication occurs, the message will override
any screen that was displayed on the monitoring
system display. For example, a steering malfunction
is indicated on the message display. The message
display prompts the operator with the Limp Home
Mode (screen) in order to continue to move the
machine with limited operation to a safe place.
Reference: S
ee Systems O
peration, KENR8246,
“D7E Track-Type Tractor Monitoring System ” for
more information.
Monitoring System Display
89
Illustration 89
The monitoring system display is located in the front
operator console.
The monitoring system display monitors the machine
op
erations,
diagnostic events, and modes of
operation. The monitoring system display is used to
change the preferred operator inputs and operation
parameters. This exercise allows additional means
for the operator to increase machine efficiency.
Monitor alert indicator – The monitoring
system display indicates a detected fault
by the moni
toring system.
If a fault indication occurs, the message will override
an
y screen that was displayed on the monitoring
system display.
Note: Y
ou may snooze the fault display from the
scre
en by pushing the OK button.
Display Readout
The digital display window provides readouts for the
Monitoring System Display.