65
WEBM1000 Operation Section (D6T LGP (OEM))
Machine Operation
Finally, if the engine is still allowed to run through
multiple forced engine shutdowns, all types of
regenerations are locked out. The DPF must be
replaced. Consult your local Cat dealer if the DPF
needs to be replaced.
Key Off Regeneration
The use of the Key Off Regeneration feature and the
Delayed Engine Shutdown feature allows the engine
to run for a time when the engine start switch is
turned to the OFF position. The key may be
removed.
Note: The
re may be regulations that define the
requir
ements for the operator and/or support
personnel to be present when the engine is running.
Leaving the machine unattended when the
engine is running may result in personal injury or
death. Before leaving the machine operator
station, neutralize the transmission, apply the
parking brake, lower work tools to the ground,
and deactivate all work tools.
Refer to Operation and Maintenance Manual,
“Parking” for more information.
Note: Leaving the machine unattended when the
engine
is running may also result in property
damage in the event of a malfunction.
Key off regeneration allows for regeneration when
t
he engine
start switch key has been removed. To
begin a key off regeneration, the soot level must be
between 15% and 100% on the soot level monitor
and/or a regeneration is in progress. The following
steps outline the procedure of a key off regeneration:
1. T
urn the engine start switch to the OFF position.
2. The engine will continue to run for 15 se
conds.
During this 15 second interval, if a regeneration
is desired, press and hold the force regeneration
switch for 2 seconds.
Note: I
f a regeneration is not desired, the machine
will initiate the delaye
d engine shutdown.
3. The key off regeneration will activate and
the key
off regeneration will last for up to 15 minutes.
Note: If at anytime the regeneration needs to be
stopped,
press and hold the disable regeneration
switch.
4. Onc
e the key off regeneration is complete, the
machine will initiate the delayed engine
shut
down.
5. The delayed engine
shutdown will
last for 5
minutes.
6. After the delayed engine shutdown has been
completed, the engine will shut down.
Delayed Engine Shutdown
The Delayed Engine Shutdown allows the engine to
run for a time after the engine start switch is turned
to the OFF position to cool the engine and the
machine system components. The engine start
switch key may be removed.
Note: Th
ere may be regulations that define the
requir
ements for the operator and/or support
personnel to be present when the engine is running.
Leaving the machine unattended when the
engine is running may result in personal injury or
death. Before leaving the machine operator
station, neutralize the transmission, apply the
parking brake, lower work tools to the ground,
and deactivate all work tools.
Refer to Operation and Maintenance Manual,
“Parking” for more information.
Note: Leaving the machine unattended when the
engine is r
unning may result in property damage in
the event of a malfunction.
Turn the engine start switch to the OFF position.
Delayed Engine Shutdown – The
delayed engine shutdown indicator will
illuminate or the following text will be
displayed, ENGIN
E COOLDOWN
ACTIVE.
Delayed engine shutdown will run for a minimum of
30 seconds
and will continue to run
until the engine
and machine system components are cooled. The
maximum run time is 10 minutes,
Note: T
o override delayed engine shutdown and
stop
the engine, turn the engine start switch to the
STOP position. Overriding delayed engine shutdown
may reduce engine and machine system component
life. A warning message and/or audible alarm will be
initiated and a fault code will be logged for improper
engine shutdown.