223
WEBM1000 Maintenance and Lubrication Section (Pipelayer Attachment
Kit)
12. See the Operation and Maintenance Manual,
“Capacities (Refill) in order to determine the
amount of hydraulic oil that is needed to fill the
hydraulic oil tank. Fill the hydraulic oil tank.
13. Inspect the filler cap gasket.
Inst
all a new gasket
if damage or wear is evident. Install the filler cap.
14. Start the engine. Run the engine for a few
minut
es. Check for leaks.
15. Maintain the oil leve
l to the “FULL” mark in sight
gauge (3). Add oil, if necessary. Stop the engine.
Hydraulic System Oil Filter -
Replace
At operating temperature, the hydraulic tank is
hot and under pressure. Hot oil and components
can cause personal injury. Do not allow hot oil or
components to contact skin. Remove the filler
cap only when the engine is stopped, and the
filler cap is cool enough to touch with your bare
hand. Remove the filler cap slowly in order to
relieve pressure.
1. Slowly remove the hydraulic tank filler cap in
order to relieve the system pressure.
2. Open the access door that is located on the right
side of the machine next to the
filler cap.