WEBM1000 Maintenance Section (D6T LGP (OEM))
Brakes, Indicators and Gauges - Test
6. Install the new belt around the pulleys.
7. When you release the tension off the belt
tensioner, the
belt tensioner will automatically
adjust the belt to the correct position. Recheck
the belt tension.
8. T
urn the battery disconnect switch to the ON
position.
9. Close the right
engine access door.
Note: If a new belt is ins
talled, recheck the belt
adjustment after 30 minutes of operation.
Brakes, Indicators and Gauges
- Test
Inspect the dash panel for broken lenses, indicator
lights, and switches.
Functional Test of the Monitoring
System Display
To ensure proper operation of Monitoring System
Display (1), check the system on a daily basis.
154
Illustration 154
The battery disconnect switch must be ON in order
to supply electrical power to the machine so that the
electrical systems will function.
ON – The engine start switch key (2)
must be turned to the ON position. This
action will
supply electrical power to the
operator compartment so that the CMS
will function.
Turn the engine start key to the ON position. The
syste
m shou
ld act in the following manner:
• The indicator lights on the monitoring system
display come on brief
ly.
• The action light comes on briefly.
• The action alarm sounds briefly.
• The pointers on the gauges point upward. Then,
the po
inters point to the left. Then, the pointers
point to the right. Then, the pointers point to the
final position.
If the system functions properly, start the engine. If
any of
the following
events occur, do not start the
engine:
• The indicator lights on the monitoring syst
em
display do not come on
.
• The action light does not come on.
• The action alarm does not sound.
Complete any necessary repairs before you start the
engine.
Braking System (Test)
If the machine moves during the test, reduce the
engine speed immediately, and engage the
parking brake.
If the machine moved while testing the brakes,
consult your Caterpillar dealer for brake
inspection and repair. Damaged brakes must be
repaired before returning the machine to
operation.
Note: Driving through the brakes in the first
speed range is possible for this machine.
Make sure that the area around the machine is clear
of per
sonnel and clear of obstacles.
Test the brakes on a dry, level surface.