184
Safety Section (Pipelayer Attachment Kit) WEBM1000
Safety Messages - 72H Pipelayer
Hydraulic Accumulator 4
Safety message (4) is located on the lower right side
of the console, below the pipelayer controls.
High Pressure Cylinder: Rapid discharging from
disconnecting or disassembly or failure to follow
the instructions and warnings could cause an
explosion, resulting in possible injury or death.
Do not expose to fire. Do not weld. Do not drill.
Do not remove any hydraulic system lines, taps
or parts until pressure has been relieved. Relieve
pressure before discharging. See Operation and
Maintenance Manual "Accumulator" for charging
and discharging. See your Dealer for tools and
detailed information. Precharge only with dry
nitrogen gas.
Free Fall Active - Do Not Operate 5
Safety message (5) is located on the right side, on
the pipelayer control box.
Dropping load hazard! The free fall control
remains live for several hours after the engine
has been stopped. Operation of the free fall
control could cause a sudden uncontrolled drop
of any supported load. Do not operate the free
fall control when personnel are near a suspended
load, even with the engine stopped. See
Operation and Maintenance Manual "Pipelayer
Operation" for complete description of control
operation.