Operation Section (D6T LGP (OEM)) WEBM1000
Machine Operation
86
Illustration 86
Note: At any time during a delayed engine
shutdown, the engine start switch may be turned to
the ON position. The machine may be placed back
into service.
Monitoring System
The monitoring system informs the operator of the
status of the machine systems. The monitoring
system informs the operator of problems or of an
impending problem.
Functional Test
When the engine key start switch is turned ON, the
monitoring system will conduct a self test. The self
test consists of the following characteristics: full
sweep of the gauge needles from the minimum
position to the maximum position, activation of all
indicators and activation of the audible alarm for
level three warnings for one second. The operator
must observe the self test to verify that the
monitoring system is working properly.
The self testing feature verifies that the modules of
t
he m
onitoring system are properly operating.
The operator must observe the outputs in order to
deter
mine if the modules are operating properly.
This self testing feature is 3 seconds long.
If the action alarm does not sound during this
test or machine monitoring displays are not
functioning, do not operate the machine until the
cause has been corrected. Machine operation
with faulty action alarms or displays could result
in injury or death as any Warning Category 3
notifications will not be relayed to the operator.
During the self test, all status indicators light.
• The action light stays illuminated.
• The
action alarm sounds once.
The monitoring panel is then in the normal operating
mode.
Action Lamp
87
Illustration 87
Monitoring system display
Action Lamp (1) – There are two action
lamps. One action lamp (1) is on the
gauge c
luster. The other action lamp is
located on the right console. The
rearward action lamp is viewed when the operator is
facing rearward.
Gauges
Hydraulic Oil Temperature (2) – The
gauge indicates the temperature of the
hydraulic oil in the hydraulic oil sump for
t
he steering and implement circuits. If the
gauge needle enters the red zone, the hydraulic
system oil is approaching 95 C (203 F). The
monitoring system display will display a warning. If
necessary, reduce the load that is on the machine
until the hydraulic oil temperature decreases.
Engine Coolant Temperature (3) – The
water temperature regulator regulates the
coolan
t temperatures. If the gauge needle
just enters the red zone, the coolant
temperature is 112 C (234 F). Increased
temperatures will sound the warning alarm.
Continued operation of the machine during the
sounding of the warning alarm or the gauge needle
in the red zone may damage the engine. Stop the
machine in a safe place and investigate the cause.