161
WEBM1000 Maintenance Section (D6T LGP (OEM))
Lift Cylinder Yoke Bearings - Lubricate
If the machine is operated under a high load and/
or under high temperature conditions, sample all
fluids at the 250 hour interval.
1. Ope
n the access cover on the right side of the
cab t
hat is in front of the hydraulic tank.
220
Illustration 220
The hydraulic oil sampling valve is shown.
2. Remove the protective cap.
3. Use 8T-9190 Fluid Sa
mpling Bottle (1) to obtain
the sample.
4. After you take a sample, remove the cap with the
pro
be from the bottle. Discard the cap with the
probe. Install the sealing cap that is provided
with 8T-9190 Fluid Sampling Bottle (1).
5. Repla
ce the protective cap.
6. Close the access cover.
Reference: Re
fer to
, “Lubricant Viscosities” in the
Maintenance Section of this manual for the correct
fluid for your machine.
Lift Cylinder Yoke Bearings -
Lubricate
(If Equipped)
221
Illustration 221
The grease fittings are on the left side of the radiator
guard and on the right side of the radiator guard.
Lubricate the bearings by applying grease to the
fittings. Use MPGM grease.
Oil Filter - Inspect
Inspect a Used Filter for Debris
222
Illustration 222
The element is shown with debris.
Use a filter cutter to cut the filter element open.
Spread apart the pleats and inspect the element for
metal and for other debris. An excessive amount of
debris in the filter element can indicate a possible
failure.
If metals are found in the filter element, a magnet
can
be used t
o differentiate between ferrous metals
and nonferrous metals.
Ferrous metals can indicate wear on steel parts and
on ca
st iron
parts.