
62
Operation Section (D6T LGP (OEM)) WEBM1000
Machine Operation
Note: Hydraulic lockout control (24) is designed to
deactivate the control levers. Disengage the locking
tab on the switch to use the hydraulic lockout
control. Press the top switch (24) to the lock position
in order to deactivate the control levers. The action
indicator for the attachment control will ensure that
the control is locked. Deactivate the control levers
before you exit the seat or before you service the
machine. The control levers should always be
deactivated when the machine is left unattended.
Reference: Y
ou may lowe
r the attachments after
you stop the engine. Refer to Operation and
Maintenance Manual, “Equipment Lowering with
Engine Stopped” for more information.
Tilt Control
80
Illustration 80
Hold (20A) – When you release the lever,
the lever returns to the HOLD position.
The movemen
t of the bulldozer blade
stops in the TILT direction.
Tilt Left (20F) – Pull the tilt lever toward
the left in order to lower the left
side of the
bulldozer blade. Faster movement of the
lever increases the moving speed of the blade.
Releasing the lever will return the lever to the HOLD
position.
Tilt Right (20G) – Push the tilt lever
toward the right in order to lower the right
side of
the bulldozer blade. Faster
movement of the lever increases the moving speed
of the blade. Releasing the lever will return the lever
to the HOLD position.
Horn (21)
Horn – Push the knob downward in
order to sound the horn. Use the horn to
alert t
he personnel. Use the horn to signal
the personnel.
Additional Operator Controls
Ground Level Service Center
81
Illustration 81
Secondary Engine Shutdown (22)
Engine Stop – Move the toggle switch to
this position in order to stop the engine
from ground lev
el.
Engine Run – With the toggle switch in
this position the machine engine
continue
s to operate.
Access Light (23)
Platform Access Lighting – Use this
toggle switch to operate the access
lighting wh
en mounting the machine.
Note: When the switch
in the ground level service
center is activated, the lights remain on for 10
minutes. The time limit of the lights is programmable.
Toggling the switch a second time will deactivate the
lights. The toggling of the switch will also turn off the
lights if the lights were activated from the cab while
exiting the machine.
Delayed Lighting Mode
This function is enabled by leaving the lights in the
ON
positio
n before turning the machine keyswitch to
the OFF position. The lights will stay on for a
configured amount of time to light the machine for
safe exit. The default is 10 minutes. The lights may
be turned off using the ground level “Access
Lighting” switch.
Jacket Water Heater (24)
Engine Starting Aid – Use this outlet to
operate the engine coolant heater, if
equipped.