102
Operation Section (D6T LGP (OEM)) WEBM1000
Parking
Idling the Engine for Extended
Periods
If the machine is parked and left running for
extended periods, set the engine speed at a slightly
higher RPM than low idle. Idling the engine at a
higher RPM ensures good engine lubrication.
Stopping the Engine if an
Electrical Malfunction Occurs
If the engine does not stop after turning the engine
start switch key to the OFF position, perform the
following procedure.
1. T
urn the key to the Emer
gency Shutdown
Override position in the event of a Delayed
Engine Shutdown (DES) or Key Off Regeneration
(KOR) is active.
2. App
ly the parking brake.
3. Lower the implement, if necessary.
4. Dismount the machine.
138
Illustration 138
5. Open the access door on the left side of the cab.
At the Ground Level Service Center, toggle the
Engine Shutdown Switch upward in order to stop
the engine.
139
Illustration 139
Rear view
6. If the engine remains operating, locate the fuel
shutoff valve. The fuel shutoff valve is under the
fuel tank at the center rear of the machine.
7. Close t
he red handle of the fuel shutoff valve in
order to
shut off the fuel supply to the engine.
Note: Do not operate the machine until the
malfun
ction has been corrected.
Leaving the Machine
1. Park on a level surface. If you must park on a
grade, block the machine.
2. Apply the servic
e brake in order to stop the
machine. Move the speed range selector to the
NEUTRAL position. Use the throttle switch to
reduce the engine speed to low idle. Engage the
parking brake.
3. Lo
wer all implements to the ground.
4. Stop the engine by turning the engine start
sw
itch k
ey to the OFF position. Remove the key.
5. Turn the key for the battery disconnect switch to
the O
FF position. Remove the key when you exit
the machine for an extended period.
6. Whe
n you dismount, use the steps and the
handholds.
Use both hands and face the
machine.