111
WEBM1000 Operation Section (D6T LGP (OEM))
Engine Starting (Alternate Methods)
Engine Starting (Alternate
Methods)
Engine Starting with Jump
Start Cables
Batteries give off flammable fumes which can
explode.
To avoid injury or death, do not strike a match,
cause a spark, or smoke in the vicinity of a
battery.
Failure to properly service the batteries may
cause peronal injury.
Prevent sparks near the batteries. They could
cause vapors to explode. Do not allow the jump
start cable ends to contact each other or the
machine.
Do not smoke when checking battery electrolyte
le
vels
.
Electrolyte is an acid and can cause personal
inj
ur
y if it contacts skin or eyes.
Always wear eye protection when starting a
ma
ch
ine with jump start cables.
Improper jump start procedures can cause an
e
xplosion
resulting in personal injury.
Always connect the battery positive (+) to battery
pos
itive (
+) and the battery negative () to battery
negative ().
Jump start only with an energy source with the
s
am
e voltage as the stalled machine.
Turn off all lights and accessories on the stalled
ma
ch
ine. Otherwise, they will operate when the
energy source is connected.
NOTICE
When starting from another machine, make sure that
the machines do no
t touch. This could prevent
damage to engine bearings and electrical circuits.
Turn on (close) the battery disconnect switch prior to
th
e boost con
nection to prevent damage to electrical
components on the stalled machine.
Severely discharged maintenance free batteries do
n
ot f
ully recharge from the alternator after jump
starting. The batteries must be charged to proper
voltage with a battery charger. Many batteries
thought to be unusable are still rechargeable.
This machine has a 24 volt starting system. Use only
th
e sa
me v
oltage for jump starting. Use of a welder
or higher voltage damages the electrical system.
Refer to Special Instruction, Battery Test Procedure,
SE
HS7633, av
ailable from your Caterpillar dealer, for
complete testing and charging information.
Use of Jump Start Cables
When the auxiliary start receptacles are not
available, use the following procedure.
1. Determine the failure of the engine to start.
Ref
erence: Refer
to Special Instruction, SEHS7768
on the use of 6V-2150 Starting/Charging Analyzer.
Use this procedure if the machine does not have a
diagnostic connector.
Reference: Also
, r
efer to Systems Operation,
SENR2947 “Starting and Charging Systems for
Machines Equipped with Diagnostic Connector”.
2. Plac
e the transmission control on the stalled
machine
in the NEUTRAL position. Engage the
parking brake switch. Lower all attachments to
the ground. Move all controls to the HOLD
position.
3. On
a stalled machine, turn the start switch key to
th
e OF
F position. Turn off the accessories.
4. On a stalled machine, turn on the battery
disconnec
t switch.
5. Move the machines together in order for the
cables t
o reach. DO NOT ALLOW THE
MACHINES TO CONTACT EACH OTHER.
6. St
op the engine on the machine that is the
electrical source.
When you use an auxiliary
power source, turn off the charging system.