219
WEBM1000 Maintenance and Lubrication Section (Pipelayer Attachment
Kit)
292
Illustration 292
Counterweight hinge pins lubrication points
Fairlead Sheave – Lubricate
293
Illustration 293
Fairlead sheave lubrication points
Lubricate one fitting in the lower sheave and
lubricate one fitting in the upper pin.
Hook and Wire Cable – Inspect
Inspect the Hook
Inspect the hook frequently. The inspections should
include observation of the hook during operation of
the hook. A designated person determines if the
conditions that are found during the inspections
constitute a hazard. The designated person will
determine if a more detailed inspection is required.
• Inspect the hook for any distortion such as bends
in
th
e hook or twists in the hook.
• Inspect the hook for any wear.
• Inspect the hook for cracks, nicks, or gouges.
• If a latch is provided, inspect the latch. Make sure
that th
e latch engages properly. Inspect the latch
for any damage. Make sure that the latch is not
malfunctioning.
• Inspect the hook assembly and the means for
s
ecu
ring the hook assembly.
• For additional information on the proper
maintenance
and on the proper inspection of
hooks, refer to "American National Standard
Institute ANSI/ASME B30.14".
Inspect Wire Cable - Boom and
Hook lines
Make a visual inspection of all running cables that
are in continuous use. Make the inspection of the
running cables on a daily basis before the machine
is placed in operation. Inspect all of the cables on a
monthly basis.
All inspections shall be performed by a designated
per
s
o
n.
Keep a dated report of the condition of the
cable on file in a location that is available to
designated personnel. Perform a close inspection of
the sections of the cable that are normally hidden
during the visual inspection and the maintenance
inspection. (This includes the sections of the cable
that pass over the sheaves.) These points are the
sections of the cable that are most likely to fail.
Note any deterioration that results in a notable loss
of
th
e original strength. (See the conditions that are
described below.) Determine if further use of the
cable will constitute a hazard.
Inspect the cable on a daily basis for the following
con
ditions: