124
Maintenance Section (D6T LGP (OEM)) WEBM1000
Maintenance Interval Schedule
Every 2000 Service Hours
Fumes Disposal Filter Element - Replace............ 152
Every 2000 Service Hours or 1 Year
Cooling System Coolant Sample (Level 2) - Obtain
........................................................................... 134
Final Drive Oil - Change
....................................... 144
Hydraulic System Oil - Change
........................... 155
Hydraulic System Oil Filter (Pilot) - Replace
........ 157
Track Roller Frame Guides - Inspect
................... 168
Every 2000 Service Hours or 2
Years
Cooling System Water Temperature Regulator - Re-
place
.................................................................. 135
Every 2500 Service Hours
Engine Valve Lash - Check/Adjust ...................... 142
Every Year
Refrigerant Dryer - Replace................................. 164
Every 3 Years After Date of
Installation or Every 5 Years After
Date of Manufacture
Seat Belt - Replace .............................................. 165
Every 4500 Service Hours
ARD Spark Plug - Replace .................................. 125
Every 5000 Service Hours
Diesel Particulate Filter - Clean/Replace ............. 136
Fuel Priming Pump - Replace
.............................. 147
Every 6000 Service Hours or 3
Years
Cooling System Coolant Extender (ELC) - Add... 131
Every 12 000 Service Hours or 6
Years
Cooling System Coolant (ELC) - Change ............ 129