Page 95
Emissions Parameters
ARD PTO Mode Stationary Regeneration
Device Enable Status
Description:
The Aftertreatment Regeneration Device (ARD)
PTO Mode Stationary Regeneration Device Enable
Status parameter allows the operator to decide if a
regeneration of the Diesel Particulate Filter ( DPF) will be
allowed during PTO Mode operation.
If programmed to Enabled, a regeneration can be
performed by using the Caterpillar Regeneration System
Force Switch. PTO Mode must be active and engine
speed between 1000 and 1850 RPM for regeneration to
occur.
Note: To enable this parameter, Factory Passwords are
required.
Available:
EPA’07 and newer C7, C9, C13 & C15 on-highway
engines
Range:
Engine Range
Cat
Default
EPA’07 and newer C7,
C9, C13 & C15
Enabled
Disabled
Disabled
Advantages:
Allows semi-automatic regeneration during PTO
operation.
Disadvantages:
None
Recommendations:
✔ Set to Disable unless the application requires a
signifi ciant amount of time in PTO mode.