Page 198
Input Selection
Engine Shutdown Override Switch /
OEM
/
Description:
The Engine Shutdown Override Switch allows the
operator to override an impending engine shutdown due
to Low Coolant Level, Low Oil Pressure, High Coolant
Temperature, or Excessive Soot Loading.
When depressed the operator will receive an additional
30 seconds engine run time before going through the
engine shutdown sequence. During the engine derate/
shutdown sequence, the Red Stop Lamp fl ashes. If
fl ashing and the Engine Shutdown Override switch is
toggled off/on/off, an additional 30 seconds of engine run
time is granted. The Red Stop Lamp will be illuminated
solid, then return to fl ashing after the 30 second timer
has expired. This switch can be toggled repeatedly to
achieve an additional 30 second of engine run time but
only when the Red Stop Lamp is fl ashing.
A diagnostic code of 71-11: Engine Shutdown Override
Occurrence is logged each time the switch is toggled.
Engine & Aftertreatment Monitoring Mode must be set
to Shutdown.
Available:
C9 Mass Transit Bus Ratings only
Range:
Engine Range
Cat
Default
C9 Mass Transit
Bus only
None
J1/P1: 6, 7, 22, 23, 35, 40, 44,
45, 46, 47, 56, 58, 59, 60
None