Page 175
Input Selection
PTO Engine RPM Set Speed Input B /
OEM
/
Description:
The PTO Engine RPM Set Speed Input B switch is used
to control the engine speed during PTO operation.
Specifi cally, this parameter is set to set engine speed
to the engine speed specifi ed by the PTO Engine RPM
Set Speed B parameter. For the PTO Engine RPM Set
Speed Input B to work properly, the PTO Confi guration
parameter must be programmed to Cab Switches,
Remote Switches, or Remote Throttle, and the PTO
Engine RPM Set Speed B parameter must be set to a
valid engine speed.
Available:
All electronically programmable on-highway engines
covered in this handbook
Range:
Engine Range Default
3126E, C7, C9 J1/P1:7, J1/P1:23 None
C-10, C-12, C-15,
C-16, C11, C13, C15
J1/P1:6, J1/P1:46, J1/P1:58,
J1/P1:60
None
EPA’07 and newer
C7, C9, C13, C15
J1/P1:6, 7, 22, 23, 35, 40, 44,
45, 46, 47, 56, 58, 59, 60
None
Advantages:
This parameter allows the operator to adjust the engine
speed to the speed specifi ed by the PTO Engine RPM Set
Speed B parameter.
Disadvantages:
None