TM 5-3805-261-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED 0013 00
0013 00-43
107 Monthly Parking
Brake Test
Be ALERT for personnel in the area while operating machine.
Always check to ensure area is clear of personnel and obstruc-
tions before starting engine, moving machine, or lowering or
raising blade. Failure to follow this warning may cause injury
or death to personnel or damage to equipment.
a. Ensure area around machine is
clear of all personnel and obsta-
cles.
b. Test brakes on hard, packed dirt.
c. Fasten seat belt before testing
brakes.
d. Start and warm up engine (WP
0005 00).
e. Ensure air system is at operating
pressure of 110±10 psi (758±69
kPa).
f. Raise blade and scarifier.
g. Operate machine in 2nd gear at
full throttle.
h. Press transmission modulator
pedal, shift transmission to neu-
tral, and apply parking brake.
Wheels do not skid. Notify
Unit Maintenance.
108 Monthly Sectionaliza-
tion
Equipment
(if Equipped)
Check sectionalization components
with the following steps:
Binding or damaged compo-
nents if required for mission.
a. Remove two mounting bolts from
control box.
b. With assistance, position control
box in mounting bracket next to left
battery box.
c. Check all cables and hoses for
damage and debris. Remove
debris. Notify Unit Maintenance if
damaged.
d. Make sure electrical connector and
all hose ends have caps installed.
ITEM
NO. INTERVAL
MAN-
HOURS
LOCATION
ITEM TO
CHECK/
SERVICE PROCEDURE
NOT FULLY MISSION
CAPABLE IF: