126 SEBU7494-06
Maintenance Section
Hydraulic System Oil Level - Check
6. Install the new
filter element by hand. When the
gasket contacts the filter element mounting base,
tighten the filter element for an additional three
quarters of a t
urn.
7. Maintain the hydraulic oil level to the middle of the
sight gauge.
Refer to Operation and Maintenance
Manual, “Hydraulic System Oil Level - Check”. Do
not overfill the hydraulic tank.
8. Inspect the gasket on the hydraulic tank filler cap
for damage. Replace the hydraulic tank filler cap,
if necessary
. Install the hydraulic tank filler cap.
9. Close the engine access door.
i01786416
Hydraulic System Oil Level -
Check
SMCS Code: 5095-535-FLV
g0095681
8
Illustration 148
Note: This film is located near the hyd raulic filler
cap on machines that are filled w ith synthetic oil.
g00926168
Illustration 149
sight gauge (type 1)
g00926177
Illustration 150
sight gauge (type 2)
1. Park the machine on level ground.
2. Lower the work tool to the ground. Turn off the
engine.
3. Wait for about five minutes before checking the
level of the hydraulic oil.
4. Maintain the oil level to the middle of the sight
gauge. Do not overfill the hydraulic tank.
i01871469
Lift Arm and
Cylinder Linkage
- Lubricate
SMCS Code:
5102-086-BD; 6107-086-BD
g00953049
Illustration 151
247, 2 67 and 277 machines