92 31200243
Operation Section
This machine has a 12 volt starting system. Use only the
same voltage for jump starting. Use of a welder or higher
voltage damages the electrical system.
Refer to Special Instruction, Battery Test Procedure,
SEHS7633, available from your Caterpillar dealer, for
complete testing and charging information.
If your battery is dead, you may need to charge the
battery at a low rate of charge. When auxiliary start
receptacles are not available, use the following
procedure:
1. Engage the parking brake on the stalled machine.
Place the transmission into neutral. Lower the
equipment to the ground. Move all of the controls to
the HOLD position.
2. Turn the engine start switch on the stalled machine to
the OFF position. Turn off all of the accessories.
3. Turn the battery disconnect switch on the stalled
machine to the ON position (if equipped).
4. Move the machine that is being used as an
electrical source near the stalled machine so that
the jump start cables reach the stalled machine. Do
not allow the machines to contact each other.
5. Engage the parking brake of the machine that is
being used as an electrical source.
6. Stop the engine of the machine that is being used
as an electrical source. If you are using an auxiliary
power source, turn off the charging system.
7. Ensure that battery caps on both machines are
tight. Ensure that the battery caps are correctly
placed. Ensure that batteries in the stalled
machine are not frozen. Make sure that the
batteries have enough electrolyte. Use a face
shield and protective clothing in order to perform
this task.
8. The positive ends of the jump start cable are red.
Connect one positive end of the jump start cable to
the positive cable terminal of the discharged
battery. Some machines have battery sets.
Note: Batteries that are in series may be in separate
compartments. Use the terminal that is connected to
the starter solenoid. This battery or battery set is
normally on the same side of the machine as the
starting motor.
Do not allow the positive cable clamps to contact any
metal except for the battery terminals.
9. Connect the other positive end of the jump start
cable to the positive cable terminal of the electrical
source.
10. Connect one negative end of the jump start cable to
the negative cable terminal of the electrical source.
11. Finally, connect the other negative end of the jump
start cable to the frame of the stalled machine. Do
not connect the jump start cable to the battery post.
Do not allow the jump start cables to contact the
following components: the fuel lines, the hydraulic
lines, and any moving parts.
12. Start the engine of the machine that is being used as
an electrical source or energize the charging
system on the auxiliary power source.
13. Wait at least two minutes before you attempt to
start the stalled machine. This will allow the
batteries in the stalled machine to partially charge.
14. Attempt to start the stalled engine. Refer to
Operation and Maintenance Manual, "Engine
Starting" for the correct starting procedure.
15. Immediately after you start the stalled engine,
disconnect the jump start cables in reverse order.