106 31200243
Maintenance Section
Axle Breathers - Clean/Replace
1. Park the machine on level ground. Fully retract the
boom and fully lower the boom. Move the
transmission control to the NEUTRAL position and
ensure that the parking brake is engaged. Shut off
the engine.
Illustration 174 g01000311
Front axle breather
Illustration 175 g00950516
Rear axle breather
2. Clean the area around the breathers. Remove the
breathers from the front and rear axles.
3. Wash the breathers in clean nonflammable
solvent. Wipe the breathers dry and check the
breathers for damage.
4. Replace the breathers if the breathers are
damaged. Install the clean breathers back into the
axles.
Backup Alarm - Test
The backup alarm is mounted at the rear of the
machine.
Turn the engine start switch to the ON position in order
to perform the test.
Apply the service brake. Move the transmission control
lever to the REVERSE position.
The backup alarm should start to sound immediately.
The backup alarm will continue to sound until the
transmission control lever is moved to the NEUTRAL
position or to the FORWARD position.
The backup alarm has one sound level. The sound level
is not adjustable.
Battery - Recycle
Always recycle a battery. Never discard a battery.
Always return used batteries to one of the following
locations:
• A battery supplier
• An authorized battery collection facility
• Recycling facility
Battery or Battery Cable -
Inspect/Replace
1. Turn the engine start switch key to the OFF
position. Turn all switches to the OFF position.
2. The battery disconnect switch (if equipped) is
located in the engine compartment above the
battery. Turn the key for the battery disconnect
switch to the OFF position. Remove the key. Refer
to Operation and Maintenance Manual, "Battery
Disconnect Switch" for further information.
3. Disconnect the negative battery cable at the battery
disconnect switch.
Note: Some machines are equipped with two
batteries. Do not allow the disconnected battery cable
to contact the battery disconnect switch or the machine.
4. Disconnect the negative battery cable from the
battery.
5. Disconnect the positive cable at the battery end.
6. Inspect the battery terminals for corrosion. Inspect
the battery cables for wear or damage.
7. If necessary, make repairs. If necessary, replace the
battery cables, the battery or the battery
disconnect switch.
8. Connect the positive cable at the battery end.
9. Connect the negative battery cable at the battery.
10. Connect the negative battery cable at the battery
disconnect switch.
11. Install the key for the battery disconnect switch.
Turn the battery disconnect switch to the ON
position.