RENR9348-01 69
Troubleshooting Section
Results:
•
OK – STOP.
i02416460
CID 0262 FMI 03 5 Volt Sensor
DC Powe r Sup ply s ho rt to
+batt
SMCS Code: 1439-038
Conditions Which G enerate This Code:
The Electroni
c Control Module (ECM) detects an
above normal voltage on the 5 volt supply.
System Respon
se:
The code is logged. The check engine lamp will
illuminate w
hile this diagnostic code is active. The
ECM sets all of the pressure sensors to the default
values.
Possible Performance Effect:
•
The engine po
wer is derated.
Troubleshooting:
Perform the following diagnostic procedure: “5 Volt
Engine Pressure Sensor Supply Circuit - Test”
Results:
•
OK – STOP.
i02416463
CID 0262 FMI
04 5 Volt Sensor
DC Powe r Sup ply s ho rt to
grou nd
SMCS Code: 1439-038
Conditions
Which Generate This Code:
The Electronic Control Module (ECM) detects a
below norm
al voltage on the 5 volt supply.
System Response:
The code is logged. The check engine lamp will
illuminate while this diagnostic code is active. The
ECM sets al
l of the pressure sensors to the default
value.
Possible P
erformance Effect:
•
The engine power is derated.
Tr oubleshooting:
Perform the following diagnostic procedure: “5 Volt
Engine Pressure Sensor Supply Circuit - Test”
Results:
•
OK – STOP.
i02445689
CID 0268 FMI 02
Check
Programmable Parameters
SMCS Code: 190
1-038
Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects one of
the following conditions:
•
At least one system configuration parameter is not
programmed.
•
At least one injector trim file is not programmed.
System Respo
nse:
The diagnostic code will only be active. The check
engine lamp w
ill illuminate while this diagnostic code
is active. Any unprogrammed parameters are set to
the default value.
Possible Performance Effect:
•
The unprogr
ammed parameters determine the
action that is taken by the ECM.
Tr oublesho
oting:
Program the missing parameter.
If a system configuration parameter has not been
programmed, refer to Troubleshooting, “System
Configurati
on Parameters”.
If an injector trim file has not been programmed,
refer to pro
gramming parameters Troubleshooting,
“Injector Trim File”.
Results:
•
OK – STOP.