34 RENR9348-01
Troubleshooting Section
2. Check the air inlet and exhaust system for
restrictions a
nd/or leaks. Refer to Systems
Operation/Testing and Adjusting, “Air Inlet and
Exhaust System”.
i02173692
Engine Oil in Coolin g System
SMCS Code: 1348-035; 1350-035
Probable Causes
•
Engine oil cooler core
•
Cylinder head gasket
Recommended Actions
Engine Oil Cooler Core
1. Inspect the engine oil cooler core for leaks. If a
leak is found, replace the oil cooler core. Refer to
Disassembly and Assembly, “Engine Oil Cooler
- Remove”.
2. Drain the crankcase and refill the crankcase with
clean engine oil. Install new engine oil filters.
Refer to the Operation and Maintenance Manual
for more information.
Cylinder Head Gasket
1. Remove the cylinder head. Refer to Disassembly
and Assembly, “Cylinder Head - Remove” for the
correct procedure.
2. Check the cylinder liner projection. Refer to
Systems Operation/Testing and Adjusting for the
correct procedure.
3. Install a new cylinder head gasket and new water
seals in the spacer plate. Refer to Disassembly
and Assembly, “Cylinder Head - Install” for the
correct procedure.
i02455784
Engine Stalls at Low RPM
SMCS Code: 1915-035
Probable Causes
•
Unit injectors
•
Fuel supply
•
Air supply
•
Engine idle
•
Accessory equi
pment
Recommended Ac
tions
Unit Injectors
1. Check for correct installation of the J1/P1 and
J2/P2 connectors for the Electronic Control
Module (ECM).
Check for correct installation of the
J300/P300 connectors for the unit injectors. Refer
to the diagnostic functional test Troubleshooting,
“Electrical
Connectors - Inspect”.
2. Perform the “Injector Solenoid Test” with the
Caterpillar
Electronic Technician (ET) in order to
determine if all of the injector solenoids are being
energized by the ECM.
3. Perform the “Cylinder Cutout Test” with Cat ET
in order to identify any injectors that might be
misfiring. R
efer to the diagnostic functional test
Troubleshooting, “Injector Solenoid Circuit - Test”.
Fuel Supply
1. Check the fuel pressure. Refer to Systems
Operation/
Testing and Adjusting.
2. Check the fuel lines for the following problems:
restrictio
ns, collapsed lines, and pinched lines. If
problems are found with the fuel lines, repair the
lines and/or replace the lines.
3. Check the fuel tank for foreign objects which may
block the fuel supply.
NOTICE
Do not crank the engine continuously for more than
30 seconds. Allow the starting motor to cool for two
minutes be
fore cranking the engine again.
4. Prime the fuel system if any of the following
procedure
s have been performed:
•
Replacement of the fuel filters
•
Service on the low pressure fuel supply circuit
•
Replacem
ent of unit injectors
Note: A sight glass in the low pressure supply line is
helpful i
n diagnosing air in the fuel. Refer to Systems
Operation/Testing and Adjusting.