152 RENR9348-01
Troubleshooting Section
D. Connect the J1/P1 ECM connector.
E. Connect a voltmeter between the loose ends of
the wire jumpers at the P1 ECM connector.
F. Restore the electrical power to the ECM.
G. Select the “Ov
erride Parameters” option from the
“Diagnostic Tests” on Cat ET.
H. Activate the o
verride for “Ether Injection”.
I. Measure the voltage at the connector for the
starting aid s
olenoid valve.
Note: The ether override will activate the solenoid for
ten seconds. T
he measurement must be taken within
this time period.
J. Remove electr
ical power from the ECM.
K. Restore the wiring to the original configuration.
Expected Result:
The voltage m
easured 24 ± 3 VDC.
Results:
•
OK – The voltage measured 24 ± 3 VDC. The
output driver for the ether relay at the ECM is
OK. The probl
em is in the harness from the
ECM to the solenoid valve. The problem may be
in a connector. Repair the harness and/or the
connector.
Replace parts, if necessary. Verify that
the problem is resolved.
•
Not OK – The v
oltage at the ECM is not 24 ± 3
VDC.
Repair: The
ECM is not providing voltage to the
circuit for the ether solenoid. Replace the ECM.
Refer to Troubleshooting, “Replacing the ECM”.
STOP.
i02450738
Fuel Filter Differential Pressure
Switch Circuit - Test
SMCS Code: 1435-038-FI
System Ope
ration Description:
Perform this procedure if you suspect that there is
aproblemi
n the circuit for the fuel filter differential
pressure switch.
This proce
dure covers the following event codes:
•
E390-1 Fuel Filter Restriction Warning
•
E390-2 Fuel Filter Restriction Derate
•
E390-3 Fuel Fil
ter Restriction Shutdown
The fuel filter differential pressure switch is used
to detect exce
ssive restriction in the fuel fi lter. The
switch is normally closed. When the fuel pressure
attheswitchreaches103±14kPa(15±2psi)the
switch will op
en. The switch is used in order to detect
a plugged fuel filter element. The Electronic Control
Module (ECM) will alert the operator of the condition.
Use this test
in order to verify that the fuel filter
differential pressure switch is operating correctly.