172 RENR9348-01
Troubleshooting Section
If a 444-05 diagnostic code was originally present,
thereisanopen
circuit in the harness or in a
connector.
Ifa444-06dia
gnostic code was originally present,
there is an short circuit in the harness or in a
connector.
Repair the harness and/or the connector. Replace
parts, if necessary. Verify that the original problem
is resolved.
STOP.
•
Not OK – Either of the following conditions exist:
The 444-05 diagnostic code is present when the
jumper wires
are shorted. The 444-06 diagnostic
code is present when the jumper wires are open.
Repair: Ther
e is a problem with the ECM. Replace
the ECM. Refer to Troubleshooting, “Replacing
the ECM” for the correct procedure. Verify that the
problem is r
esolved.
STOP.
Test Step 6. Check for Battery Voltage at
the Input f or the Secondary Circuit at the
SMMS
A. Turn the ba
ttery disconnect switch to the ON
position.
B. Connect a t
est lamp between the +Battery terminal
of the SMMS and the engine ground stud.
C. Observe t
he test lamp.
D. Turn the battery disconnect switch to the OFF
position
.
Expected Result:
The test lamp turns on.
Results:
•
OK – The test lamp turns on. Battery voltage is
reaching
theSMMS.ProceedtoTestStep7.
•
Not OK – The test lamp does not turn on.
Repair: Battery voltage is not reaching the
secondary circ
uit of the SMMS. Ensure that the
circuit breaker for the SMMS is not tripped. There
may be an open circuit in the wiring between the
battery and th
e SMMS. There may be a problem
with a connection or the harness wiring. Repair the
circuit. Replace parts, if necessary. Verify that the
problem is re
solved.
STOP.
Test Step 7. Check for Voltage Output at
the Start Relay
A. Remove the w
ire from the output terminal for the
secondary circuit of the SMMS.
B. Turn the bat
tery disconnect switch to the ON
position.
C. Connect a te
st lamp between the output terminal
for the secondary circuit of the SMMS and the
engine ground stud.
D. Turn the battery disconnect switch to th e ON
position.
E. Crank the engine.
F. Observe th
e test lamp.
G. Turn the battery disconnect switch to the OFF
position.
Expected Result:
Thetestlampturnedonwhentheenginewas
cranked.
Results:
•
OK – The tes
t lamp turned on when the engine
was cranked.
Repair: Th
eSMMSandthecircuitareOK.The
problem is in the circuit for the starting motor
solenoid. There may be a problem with the
solenoid
or the starting motor. Repair the circuit
or the starting motor. Replace parts, if necessary.
Verify that the original problem is resolved.
STOP.
•
Not OK – Th
e test lamp did not turn on when the
engine was cranked.