158 RENR9348-01
Troubleshooting Section
Test Step 1. Inspect the Electrical
Connectors and the Wiring
Electrical shock hazard. The electronic unit injec-
tor system uses 90-120 volts.
A. Remove the electrical power from the ECM.
g01166729
Illustration 87
Left sid
e engine view (typical example)
(1) J2/P2 ECM connectors
(2) R1/P3 Injector valve c over entry connectors (right b ank)
(3) R1/P4 Injector valve cover entry con nectors (left ba nk)
B. Thoroughly inspect connectors (1), (2), and (3).
Refer to Troubleshooting, “Electrical Connectors
- Inspect
”.
g01202827
Illustration 88
P2 terminals that are as sociated with the injector solenoids
(P2-18) Injector 8 return
(P2-21) Injector 10 return
(P2-22) Injector 4 return
(P2-31) Injector 6 return
(P2-42) Injector 12 return
(P2-50) Injector 2 return
(P2-58) Injectors 10 & 12 s upply
(P2-67) Injectors 6 & 8 supply
(P2-68) Injectors 2 & 4 supply
(P2-99) Injectors 9 & 11 supp ly
(P2-104) Injectors 1 & 3 supply
(P2-105) Injector 11 r eturn
(P2-106) Injector 5 return
(P2-107) Injector 9 return
(P2-108) Injector 7 return
(P2-115) Injectors 5 & 7 supply
(P2-116) Injector 1 return
(P2-118) Injector 3 return