RENR9348-01 115
Troubleshooting Section
Repair: The ECM is properly reading the
switch input. T
here may be an intermittent
problem in the harness or in a connector. If an
intermittent electrical problem is suspected, refer to
Troubleshoot
ing, “Electrical Connectors - Inspect”
for troubleshooting information.
STOP.
•
Not OK – The status is “LOW” when the jumper
wire is conne
cted.
Repair: The ECM is not reading the switch input.
Replace the E
CM. Refer to Troubleshooting,
“Replacing the ECM”.
STOP.
i02378207
Electrical C
onnectors - Insp ect
SMCS Code: 7553-040-WW
System Operation Description:
Most electri
cal problems are caused by poor
connections. The following procedure will assist in
detecting problems with connectors and with wiring.
If a problem
is found correct the condition and verify
that the problem is resolved.
Intermitte
nt electrical problems are sometimes
resolved by disconnecting and reconnecting
connectors. It is very important to check for diagnostic
codes imme
diately before disconnecting a connector.
Also check for diagnostic codes after reconnecting
the connector. If the status of a diagnostic code is
changed du
e to disconnecting and reconnecting a
connector, there are several possible reasons. The
likely reasons are loose terminals, improperly crimped
terminal
s, moisture, corrosion, and inadequate
mating of a connection.
Follow th
ese guidelines:
•
Always use a 1U-5804 CrimpTooltoservice
Deutsch H
D and DT connectors. Never solder the
terminals onto the wires. Refer to “SEHS9615,
Servicing Deutsch HD and DT Style Connectors”.
•
Always use a 147-6456 Wedge Removal Tool to
remove wedges from DT connectors. Never use a
screwdr
iver to pry a wedge from a connector.
•
Always use a breakout harness for a voltmeter
probe or
a test light. Never break the insulation
ofawireinordertoaccesstoacircuitfor
measurements.
•
If a wire is cut, always install a new terminal for
the repair.
The c onnection of any electrical equipment and
the disconnection of any electrical equipment may
cause an explosion hazard which may result in in-
jury or death. Do not connect any electrical equip-
ment or disconnect any electrical e quipment in an
explosive atmosphere.
Test Step 1. Check Connectors for
Moisture and Corrosion
g01131211
Illustration 37
Leaky seal at the connector (typical example)
A. Inspect all wiring harnesses. Ensure that the
routing of the wiring harness allows the wires to
enter the face of each connector at a perpendicular
angle. Otherwise, the wire will deform the seal
bore. Refer to Illustration 37. This will create a
path for the entrance of moisture. V erify that the
seals for the wires are sealing correctly.