24 RENR9348-01
Troubleshooting Section
Parameter Tabl
e
Table 9
System Configuration Parameters
Parameter Available Range or Options Default
Required
Password
Selected Engine Ratings
Rating Number
Software Dependent
None
Rated Frequency
Software Dependent Read Only
(1)
Rated Engine Speed Software Dependent Read Only
(1)
Rated Real Genset Power Kilowatts (if applicable) Rated power Read Only
(1)
Rated Apparent Genset Power Kilowatts (if applicable) Rated power Read Only
(1)
Rating Configuration Software Dependent Read Only
(1)
Test Spec Software Dependent Read Only
(1)
ECM Identification Parameters
Equipment ID 17 alphanumeric characters Blank Customer
Engine Seri
al Number 0XX00000 or XXX00000 Blank Factory
ECM Serial Number
Hardware Dependent Blank
Read Only
(1)
Software Group Part Number Software Dependent Read Only
(1)
Software Group Release Date Software Dependent Read Only
(1)
Software Group Description Software Dependent Read Only
(1)
Security Access Parameters
Total Tattletale 0 to 65535 0 Read Only
(1)
Engine/Gear Parameters
Engine Accel. Rate 5 - 2000 rpm/sec 500 Customer
Low Idle Speed 600 to 1200 rpm 1200 Customer
Engine Speed Droop 0.0 - 8.0 % 3.0 % Customer
Droop/Isochronous Switch Enable Enabled or Disabled Disabled Customer
Droop mode selection Droop or Isochronous Isochronous
Customer
I/O Configuration Parameters
Ether Control
Installed or Uninstalled Uninstalled
Customer
Desired Speed Input Configuration
PWM
CAN Input
0-5VDC
CAN Input Customer
Engine State Control Input Configuration CAN Input or Uninstalled CAN Input Customer
Cooldown Duration
0 - 233 seconds 0 seconds
Customer
Prelube Duration 0 - 210 seconds 0 seconds Customer
Cranking Duration 0 - 60 s econds 30 seconds Customer
Maximum Number of Crank Cycles 0 - 10 cycles 5 cycles Customer
Secondary Desired Speed Input Configuration
PWM
CAN Input
0-5VDC
Unistalled
Unistalled
Customer
(continued)