124 RENR9348-01
Troubleshooting Section
g01207957
Illustration 53
Terminal locations for the e ngine interface connector
(Terminal 4) +Battery
(Terminal 23) Relay control
g01207940
Illustration 54
Terminal locations for the ECM relay and the connector (typical
example)
(4) ECM relay
(Terminal 1) +Battery
(Terminal 2) Relay ground
(Terminal 3) Electrical power to the ECM
(Terminal 5) Relay control
C. Perform a 45 N (10 lb) pull test on each of the
wires in the ECM connectors and the connector
for the ECM relay.
D. Check the torque of the allen head screws for
the ECM connectors. Refer to Troubleshooting,
“Electrical Connectors - Inspect” for the correct
torque values.
E. Check the harness and the wiring for abrasion and
for pinch points from the batteries to the ECM.
Expected Result:
All connectors, pins, and sockets are completely
coupled and/or inserted, and the harness and wiring
are free of corrosion, of abrasion and of pinch points.
Results:
•
OK – The connectors and wiring appear to be OK.
ProceedtoTestStep2.
•
Not OK – The connectors and/or wiring are not
OK.
Repair: Repair the wiring and/or the connectors.
Replace parts, if necessary. Verify that the original
problem has be
en resolved.
STOP.
Test Step 2. Chec k the Battery Voltage at
the ECM
A. Disconnect t
he J1/P1 ECM connector.
B. Turn the battery disconnect switch to th e ON
position.
C. Measure the voltage between P1-48 (+Battery)
and P1-61 (−
Battery).
D. Measure the voltage between P1-52 (+Battery)
and P1-63 (−
Battery).
E. Measure the voltage between P1-53 (+Battery)
and P1-65 (−
Battery).
F. Measure the voltage between P1-55 (+Battery)
and P1-67 (−
Battery).
G. Measure the voltage between P1-57 (+Battery)
and P1-69 (
−Battery).
H. Measure the voltage between P1-70 (keyswitch)
and P1-63 (
−Battery).
I. Turn the battery disconnect switch to the OFF
position.
Expected Result:
The measured voltage is between 22.0 VDC and
27.0 VDC.
Results:
•
OK – The mea
sured voltage is between 22.0 VDC
and27.0VDC.
Repair: Th
e ECM is receiving the correct voltage.
There may be an intermittent problem in the
harness or in a connector. If an intermittent
conditio
n is suspected, refer to the diagnostic
functional test Troubleshooting, “Electrical
Connectors - Inspect” for details.
STOP.