130 RENR9348-01
Troubleshooting Section
Results:
•
OK – The measurements agree with the results
that are stated above. The emergency stop switch
is operating c
orrectly. There may be a problem in
the harness between the emergency stop switch
and the engine interface connector. Connect the
connectors f
or the emergency stop switch. Proceed
to Test Step 5.
•
Not OK – The me
asurements did not agree with
the results that are stated above.
Repair: Ther
e is a problem with the emergency
stop switch. Replace the switch. Restore all wiring
to the original configuration. Verify that the repair
resolves the
original problem.
STOP.
Test Step 5. Check the Harness Between
the Connector for the Emergency
Stop Switch and the Engine Interface
Connector
A. Ensure tha
t the emergency stop switch is in the
RUN position.
B. Measure t
he resistance between terminals 4 and
23 on the switch side of the engine interface
connector.
An open circuit condition is the correct
measurement with the emergency stop switch in
the RUN po
sition.
C. Place the emergency stop switch in the STOP
positio
n.
D. Again, measure the resistance between terminals
4 and 23 o
n the switch side of the engine interface
connector.
Ashortc
ircuit condition is the correct measurement
with the emergency stop switch in the STOP
position.
Expected Result:
The meas
urements agree with the results that are
stated above.
Result
s:
•
OK – The measurements agree with the results
that ar
e stated above. The harness between the
emergency stop switch and the engine interface
connector is OK. There may be a problem in the
harnes
s between the engine interface connector
and the ECM relay. Connect the connectors for the
engine interface connector. Proceed to Test Step 6.
•
Not OK – The measurements did not agree with
the results tha
t are stated above.
Repair: There is a problem in the circuit between
the engine int
erface connector and the emergency
stop switch. Repair the harness and/or the
connectors. Replace parts, if necessary. Verify that
the repair re
solves the original problem.
STOP.
Test Step 6. Check the Operation of the
Emergency S top Switch
A. Ensure that t
he battery disconnect switch is in the
OFF position.
B. Disconnect t
he connector from the ECM relay.
C. Place the emergency stop switch in the RUN
position.
D. Turn the battery disconnect switch to th e ON
position.
E. Measure the voltage between terminal 5 of the
connector f
or the ECM relay and the engine
ground stud.
The correct
voltage is zero volts.
F. Place the emergency stop switch in the STOP
position.
G. Again, measure the voltage between terminal 5 of
the connec
tor for the ECM relay and the engine
ground stud.
The correc
t voltage is 24 ± 3 VDC.
H. Turn the battery disconnect switch to the OFF
position.
I. Connect the connector for the ECM relay.
Expected Result:
The voltag
e at the ECM relay is zero volts with the
emergency stop switch in the RUN position and the
voltage at the ECM relay is 24 ± 3 VDC with the
emergenc
y stop switch in the STOP position.
Results:
•
OK – The voltages are correct for the conditions
that are stated above.