92
Maintenance Section
Backup Alarm - Test
Note: The oscillation bearings are lubricated by
using two remote grease fittings. These fittings are
located behind the small access door on the left
side of the machine.
1. Wipe all fittings before any lubricant is applied.
2. Fitting (1) lubricates the front oscillation bearing
of the rear axle. Fitting (2) lubricates the rear
oscillation bearing of the rear axle.
i01713195
Backup Alarm - Test
SMCS Code: 7406-081
1. Turn the engine start switch key to the ON
position in order to perform the test.
2. Apply the service brake.
g00783907
Illustration 131
3. Move the transmission direction control lever to
the REVERSE position.
g00782208
Illustration 132
The alarm should start to sound immediately. The
alarm will continue to sound until the transmission
direction control lever is moved to the NEUTRAL
position or to the FORWARD position.
Reference: For more information, refer to Operation
and Maintenance Manual, “Backup Alarm”.
i01558375
Battery - Clean
SMCS Code: 1401-070
g00809805