100
Maintenance Section
Circuit Breakers - Reset
i01558427
Circuit Breakers - Reset
SMCS Code: 1420-529
Circuit Breaker Reset – Push the button
in order to reset the circuit breakers. The
button will stay depressed if the circuit is
working properly. Check the appropriate electrical
circuit if the button does not stay depressed.
g00809834
Illustration 148
Circuit breakers are located on the fuse panel at
the rear of the cab.
Seat Air Compressor (1) – 15 amp
Fan Motor (2) – 15 amp
g00809837
Illustration 149
Two circuit breakers are located on the right side of
the engine compartment below the air cleaner.
Alternator (3) – 80 amp
Main Circuit (4) – 80 amp
i01558459
Cooling System Coolant
(DEAC) - Change
SMCS Code: 1350-044
Pressurized system: Hot coolant can cause seri-
ous burn. To open cap, stop engine, wait until ra-
diator is cool. Then loosen cap slowly to relieve
the pressure.
NOTICE
Care must be taken to ensure that fluids are contained
during performance of inspection, maintenance, test-
ing, adjusting and repair of the product. Be prepared to
collect the fluid with suitable containers before open-
ing any compartment or disassembling any compo-
nent containing fluids.
Refer to Special Publication, NENG2500, “Caterpillar
Tools and Shop Products Guide” for tools and supplies
suitable to collect and contain fluids on Caterpillar
products.
Dispose of all fluids according to local regulations and
mandates.
Note: This procedure pertains to Caterpillar Diesel
Engine Antifreeze/Coolant (DEAC) only. This
procedure does not pertain to machines that are
shipped from the factory with Extended Life Coolant
(ELC) or to machines that are maintained with
Extended Life Coolant (ELC).
Drain the coolant whenever the coolant is dirty or
whenever the coolant is foaming.
1. Stop the engine and allow the engine to cool.
2. Slowly loosen the cooling system pressure cap
in order to relieve system pressure.
3. Remove the drain plug on the bottom left side of
the radiator. Allow the coolant to drain from the
cooling system into a suitable container. Install
the drain plug.
4. Replace the water temperature regulator.