97
Excavator Supplement for 3066 Engine
Disassembly and Assembly Section
•lustration 379
6. Close the side door (1).
WARNING
Personal injury can result from contact with refrig-
erant.
Contact with refrigerant can cause frost bite. Keep
face and hands away to help prevent injury.
Protective goggles must always be worn when re-
frigerant lines are opened, even if the gauges in-
dicate the system is empty of refrigerant.
Always use precaution when a fitting is removed.
Slowly loosen the fitting. If the system is still under
pressure, release it slowly in a well ventilated area.
Personal injury or death can result from inhaling
refrigerant through a lit cigarette.
Inhaling air conditioner refrigerant gas through a
lit cigarette or other smoking method or inhaling
fumes released from a flame contacting air con-
ditioner refrigerant gas, can cause bodily harm or
death.
Do not smoke when servicing air conditioners or
wherever refrigerant gas may be present.
Use a certified recovery and recycling cart to prop-
erly remove the refrigerant from the air condition-
ing system.
7. Evacuate the air conditioning system.
Reference: Evacuate the system. Refer to Testing
and Adjusting, "Refrigerant System - Evacuate"
for the correct procedure.
Reference: Refer to Testing and Adjusting,
"Refrigerant System - Charge" for the correct
procedure.
9. Check the entire air conditioning system for
leaks.
Note: Use a 4C-2964 Electronic Leak Detector to
check for leaks.
Hood - Remove and Install
SMCSCode: 7251-010
Removal Procedure
Illustration 380
1. Open hood (1).
Illustration 381
2. Fasten a suitable lifting device to hood (1).
8. Charge the air conditioning system. The correct
charge is 1.1 kg (2.42 lb).